------------------ Framework ChangeLog -----------------
EquipmentLib.dll Change Log
=======================================
Last Modified Date: 17 April 2026 6:26:52 AM
Updates: Updated Keysight M8040 code to support more pattern loading


GRLSinkTestModule.dll Change Log
=======================================
Last Modified Date: 04 May 2026 5:09:12 AM
Updates: Added Margin Test Settings Tab


GRLBaseFramework.dll Change Log
=======================================
Last Modified Date: 21 December 2025 13:41:22 PM
Updates: build to .net 4.72 allow expired application to load  but disabled report and run fix issue on generate specific test for PDF report for PLL and Tx App


GRLPDFramework.dll Change Log
=======================================
Last Modified Date: 12 January 2026 6:33:20 AM
Updates: Iniital Commit


AppFramework.dll Change Log
=======================================
Last Modified Date: 23 July 2026 2:49:40 AM
Updates: Make the Input dialog always bring to front. Set min samplingrate for UXR is 128 instaed of 100


GRL.Server.dll Change Log
=======================================
Last Modified Date: 12 August 2026 6:33:17 AM
Updates: Update GRLPS logo


------------------ Application ChangeLog -----------------
- PCIE PLL Test Application v1.00.40+
    - Added GRL remote server transfer support for Keysight scopes

- PCIE PLL Test Application v1.00.51
    - Added support for Gen6 testing
    - Usability enhancements for GRL Remote Proxy Server

- PCIE PLL Test Application v1.00.55
    - Fixed script issue where some "padding" values in the TIE waveforms are not 9e36, causing the filtering to fail. 
    - Fixed saved waveform not placed in correct default folder for each speed, and end up only persisting lastest speed result

- PCIE PLL Test Application v1.00.58
    - Fixed Gen6 toggle

- PCIE PLL Test Application v1.00.59
    - Fixed Tek Dual ATI Gen6 setup file incorrect cauisng the scope CH1 signal to be "corrupted". Only recovery after corruption is scope reboot.

- PCIE PLL Test Application v1.00.60
    - Fixed bug when pinging GRL Remote Server causing test flows on Keysight scope with sampling points exceeding 17Mpts to fail.

- PCIE PLL Test Application v1.00.61
    - Added "Beta" label to Gen6 test condition

- PCIE PLL Test Application v1.00.62
    - For Keysight scopes, if running on local scope (127.0.0.1), now the scope firmware will directly save the waveform to the intended path.

- PCIE PLL Test Application v1.00.65
    - Removed AutoReset config

- PCIE PLL Test Application v1.00.66
    - Added config "Clock Recovery" to enable user to manually configure clock recovery.

- PCIE PLL Test Application v1.00.67
    - Fixed Gen6 test permutations.

- PCIE PLL Test Application v1.00.68
    - Renamed "Limit Set" config to "16GT/s Limit Set" to clear up ambiguity.

- PCIE PLL Test Application v1.00.69
    - Fixed issue with UXR Differential Partner setting not being set correctly

- PCIE PLL Test Application v1.00.70
    - Made UI changes to seperate out Gen6 HSTP pattern

- PCIE PLL Test Application v1.00.73
    - Added config to configure memory depth for SJ calibration test.

- PCIE PLL Test Application v1.00.76
    - Added additional sleep time to UXR scope during SJ calibration.

- PCIE PLL Test Application v1.00.77
    - Added "Min Hold" measurement method.

- PCIE PLL Test Application v1.00.78
    - Added license for Gen6.

- PCIE PLL Test Application v1.00.80
    - Fixed Lower Bandwidth limit for Gen6 and removed Min Peaking checking.

- PCIE PLL Test Application v1.00.82
    - Updated binaries for GRL Remote Server due to issues encountered.

- PCIE PLL Test Application v1.00.83
    - Fixed connection diagram for Gen6.

- PCIE PLL Test Application v1.00.85
    - Changed the default memory length for Gen6.
    - Fixed long acquisition issues encountered in Keysight and Tek scopes.

- PCIE PLL Test Application v1.00.86
    - Fixed an autoscale bug in Keysight scopes.

- PCIE PLL Test Application v1.00.87
    - Removed seperate SJ calibration for Gen6.

- PCIE PLL Test Application v1.00.89
    - Initial implementation for increased frequency spacing below 500KHz.