------------------ Framework ChangeLog -----------------
EquipmentLib.dll Change Log
=======================================
Last Modified Date: 21 December 2025 13:26:37 PM
Updates: Build for .net 4.72 MP1900 added VendorName


GRLSinkTestModule.dll Change Log
=======================================
Last Modified Date: 21 December 2025 13:41:34 PM
Updates: build for .net 4.72


GRLBaseFramework.dll Change Log
=======================================
Last Modified Date: 21 December 2025 13:41:22 PM
Updates: build to .net 4.72 allow expired application to load  but disabled report and run fix issue on generate specific test for PDF report for PLL and Tx App


GRLPDFramework.dll Change Log
=======================================
Last Modified Date: 12 January 2026 6:33:20 AM
Updates: Iniital Commit


AppFramework.dll Change Log
=======================================
Last Modified Date: 09 February 2026 1:03:03 AM
Updates: Add Show Connection Diagram


GRL.Server.dll Change Log
=======================================
Last Modified Date: 23 December 2025 14:47:47 PM
Updates: Fix issue on page not loading when v5 seq file


------------------ Application ChangeLog -----------------
- USB4 V2 Rx Test Application v00.00.001
    Initialize

- USB4 V2 Rx Test Application v01.00.05
    Support ETT and Frequency variation
    

- USB4 V2 Rx Test Application v01.00.14
    -Support Scope Intrinsic Waveform Capture
        -Support Link Operatin Margin Evaluation for each Lane

- USB4 V2 Rx Test Application v01.00.16
    -Fixed Voltage Swing calibration write parameter issue

- USB4 V2 Rx Test Application v01.00.17
    -Fixed bug for calibrate frequency variation can not get case 2 voltage swing parameter 

    Test on MP1900 software version 9.01.00.29
    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.52.00301

    Test on USB4 Sigtest rev. 0.9
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Rx Test Application v01.00.21
    -Fixed DM frequency set to 2GHz issue, now will set to 10GHz

    Test on MP1900 software version 9.01.00.29
    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.52.00301

    Test on USB4 Sigtest rev. 0.9
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Rx Test Application v01.00.22
    -Update test connection diagram

- USB4 V2 Rx Test Application v01.00.23
    -Update configuration

- USB4 V2 Rx Test Application v01.00.24
    -Update Frequency Variation for MP1900 FW v10.20.00.34
    -Support MP1900 Full Module 

    Test on MP1900 software version v10.02.00.34
    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.52.00301

    Test on USB4 Sigtest rev. 0.95
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Rx Test Application v01.00.25
    -Fixed connection diagram bug

- USB4 V2 Rx Test Application v01.00.28
    -Calibration will not click the SSC Start button

- USB4 V2 Rx Test Application v01.00.29
    -Support MP1900 Standard mode for Full module

- USB4 V2 Rx Test Application v01.00.31
    -Update connection diagram for MP1900 PAM4 standard and handle polarity for both standard

- USB4 V2 Rx Test Application v01.00.32
    -Add Sigtest version 0.9 and 0.95

- USB4 V2 Rx Test Application v01.00.33
    -Add configuration of frequency variation test cycle
    -Update connection diagram support PAM4 standard mode with Noise Module MU195050A

- USB4 V2 Rx Test Application v01.00.34
    -Remove LRD test

- USB4 V2 Rx Test Application v01.00.36
    -Support using preset calibration result for test

- USB4 V2 Rx Test Application v01.00.37
    -Fixed "Pj Magnitude Adjustment" limit

- USB4 V2 Rx Test Application v01.00.38
    -Scope AUX Trigger setting will be set property for Frequency Variation Calibration item 

- USB4 V2 Rx Test Application v01.00.39
    -Added preset coefficient error diagram for preset calibration

- USB4 V2 Rx Test Application v01.00.40
    -Support BERT Insertion Loss Compensation calibration

    Test on MP1900 software version v10.03.02.02

- USB4 V2 Rx Test Application v01.00.41
    -Fixed bug for write latest preset value for TER test

- USB4 V2 Rx Test Application v01.00.42
    -Update aggressor calibration limit to CTS v0.95

- USB4 V2 Rx Test Application v01.00.44
    - Speed up open SW speed
    - Support PJ margin test
    - Support type II clock switch

- USB4 V2 Rx Test Application v01.00.46
    - Correct error counter check phase limit

- USB4 V2 Rx Test Application v01.00.47
    - Support concurrent calibration of ACCM and SNDR

- USB4 V2 Rx Test Application v01.00.48
    - Correct test item typo

- USB4 V2 Rx Test Application v01.00.50
    - Support LFPS calibration and test

- USB4 V2 Rx Test Application v01.00.51
    - Fixed the aggressor signal calibration save singal-ended issue

- USB4 V2 Rx Test Application v01.00.53
    - Update LFPS calibration procedure

- USB4 V2 Rx Test Application v01.00.55
    - Reduce BERT output signal amplitude for insertion loss compensation


- USB4 V2 Rx Test Application v01.00.56
    - Update LFPS Calibration procedure LFPS setup 8 using scope measurement


- USB4 V2 Rx Test Application v01.00.59
    - Voltage swing calibration will reset BERT

- USB4 V2 Rx Test Application v01.00.61
    - Bug Fixed

- USB4 V2 Rx Test Application v01.00.63
    - Add KS ENA calibration item

- USB4 V2 Rx Test Application v01.00.68
    - Fixed Insertion loss compensation setting issue

- USB4 V2 Rx Test Application v01.00.69
    - Update SNDR limit to 34 for CTS v1.0

- USB4 V2 Rx Test Application v01.00.75
    - Remove "BERT Assembly Step Response Extraction Swing Calibration"
    - SW will copy BERT_SDD21 waveform file to Channel Worst Case Condition Files path automatically

- USB4 V2 Rx Test Application v01.00.78
    - Add ETT semaphore function
    - Add skip Pj Magnitude Adjustment config for TER test, this function will not recall Pj Magnitude Adjustment result for TER test.

- USB4 V2 Rx Test Application v01.00.80
    - Support LRD Stand Along Test
    - Enhance Pj Adj algorithm 

- USB4 V2 Rx Test Application v01.00.82
    - Fixed LRD script bug

- USB4 V2 Rx Test Application v01.00.83
    - Fixed generate report issue