------------------ Framework ChangeLog -----------------
EquipmentLib.dll Change Log
=======================================
Last Modified Date: 04 September 2026 2:45:14 AM
Updates: Added KS 2 ch scope


GRLSinkTestModule.dll Change Log
=======================================
Last Modified Date: 04 September 2026 2:46:16 AM
Updates: Add Param for default config


GRLBaseFramework.dll Change Log
=======================================
Last Modified Date: 04 September 2026 2:46:52 AM
Updates: Update dll


AppFramework.dll Change Log
=======================================
Last Modified Date: 04 September 2026 15:59:37 PM
Updates: Handle the same host address for Tek Scope


GRL.Server.dll Change Log
=======================================
Last Modified Date: 04 September 2026 2:49:58 AM
Updates: Update dll


------------------ Application ChangeLog -----------------
- USB4 V2 Rx Test Application v00.00.001
    Initialize

- USB4 V2 Rx Test Application v01.00.05
    Support ETT and Frequency variation
    

- USB4 V2 Rx Test Application v01.00.14
    -Support Scope Intrinsic Waveform Capture
        -Support Link Operatin Margin Evaluation for each Lane

- USB4 V2 Rx Test Application v01.00.16
    -Fixed Voltage Swing calibration write parameter issue

- USB4 V2 Rx Test Application v01.00.17
    -Fixed bug for calibrate frequency variation can not get case 2 voltage swing parameter 

    Test on MP1900 software version 9.01.00.29
    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.52.00301

    Test on USB4 Sigtest rev. 0.9
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Rx Test Application v01.00.21
    -Fixed DM frequency set to 2GHz issue, now will set to 10GHz

    Test on MP1900 software version 9.01.00.29
    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.52.00301

    Test on USB4 Sigtest rev. 0.9
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Rx Test Application v01.00.22
    -Update test connection diagram

- USB4 V2 Rx Test Application v01.00.23
    -Update configuration

- USB4 V2 Rx Test Application v01.00.24
    -Update Frequency Variation for MP1900 FW v10.20.00.34
    -Support MP1900 Full Module 

    Test on MP1900 software version v10.02.00.34
    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.52.00301

    Test on USB4 Sigtest rev. 0.95
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Rx Test Application v01.00.25
    -Fixed connection diagram bug

- USB4 V2 Rx Test Application v01.00.28
    -Calibration will not click the SSC Start button

- USB4 V2 Rx Test Application v01.00.29
    -Support MP1900 Standard mode for Full module

- USB4 V2 Rx Test Application v01.00.31
    -Update connection diagram for MP1900 PAM4 standard and handle polarity for both standard

- USB4 V2 Rx Test Application v01.00.32
    -Add Sigtest version 0.9 and 0.95

- USB4 V2 Rx Test Application v01.00.33
    -Add configuration of frequency variation test cycle
    -Update connection diagram support PAM4 standard mode with Noise Module MU195050A

- USB4 V2 Rx Test Application v01.00.34
    -Remove LRD test

- USB4 V2 Rx Test Application v01.00.36
    -Support using preset calibration result for test

- USB4 V2 Rx Test Application v01.00.37
    -Fixed "Pj Magnitude Adjustment" limit

- USB4 V2 Rx Test Application v01.00.38
    -Scope AUX Trigger setting will be set property for Frequency Variation Calibration item 

- USB4 V2 Rx Test Application v01.00.39
    -Added preset coefficient error diagram for preset calibration

- USB4 V2 Rx Test Application v01.00.40
    -Support BERT Insertion Loss Compensation calibration

    Test on MP1900 software version v10.03.02.02

- USB4 V2 Rx Test Application v01.00.41
    -Fixed bug for write latest preset value for TER test

- USB4 V2 Rx Test Application v01.00.42
    -Update aggressor calibration limit to CTS v0.95

- USB4 V2 Rx Test Application v01.00.44
    - Speed up open SW speed
    - Support PJ margin test
    - Support type II clock switch

- USB4 V2 Rx Test Application v01.00.46
    - Correct error counter check phase limit

- USB4 V2 Rx Test Application v01.00.47
    - Support concurrent calibration of ACCM and SNDR

- USB4 V2 Rx Test Application v01.00.48
    - Correct test item typo

- USB4 V2 Rx Test Application v01.00.50
    - Support LFPS calibration and test

- USB4 V2 Rx Test Application v01.00.51
    - Fixed the aggressor signal calibration save singal-ended issue

- USB4 V2 Rx Test Application v01.00.53
    - Update LFPS calibration procedure

- USB4 V2 Rx Test Application v01.00.55
    - Reduce BERT output signal amplitude for insertion loss compensation


- USB4 V2 Rx Test Application v01.00.56
    - Update LFPS Calibration procedure LFPS setup 8 using scope measurement


- USB4 V2 Rx Test Application v01.00.59
    - Voltage swing calibration will reset BERT

- USB4 V2 Rx Test Application v01.00.61
    - Bug Fixed

- USB4 V2 Rx Test Application v01.00.63
    - Add KS ENA calibration item

- USB4 V2 Rx Test Application v01.00.68
    - Fixed Insertion loss compensation setting issue

- USB4 V2 Rx Test Application v01.00.69
    - Update SNDR limit to 34 for CTS v1.0

- USB4 V2 Rx Test Application v01.00.75
    - Remove "BERT Assembly Step Response Extraction Swing Calibration"
    - SW will copy BERT_SDD21 waveform file to Channel Worst Case Condition Files path automatically

- USB4 V2 Rx Test Application v01.00.78
    - Add ETT semaphore function
    - Add skip Pj Magnitude Adjustment config for TER test, this function will not recall Pj Magnitude Adjustment result for TER test.

- USB4 V2 Rx Test Application v01.00.80
    - Support LRD Stand Along Test
    - Enhance Pj Adj algorithm 

- USB4 V2 Rx Test Application v01.00.82
    - Fixed LRD script bug

- USB4 V2 Rx Test Application v01.00.83
    - Fixed generate report issue

- USB4 V2 Rx Test Application v01.00.84
    - Fixed apply BERT insertion loss compensation value for case 2 TER test issue

- USB4 V2 Rx Test Application v01.00.85
    - Skip BERT Insertion Loss Compensation for case 1

- USB4 V2 Rx Test Application v01.00.86
    - Add Margin Test configuration

- USB4 V2 Rx Test Application v01.00.87
    - Support LRD SigTest v0.86

- USB4 V2 Rx Test Application v01.00.88
    - Add ETT DUT Type configuration

- USB4 V2 Rx Test Application v01.00.89
    - Now can read ETT retimer result

- USB4 V2 Rx Test Application v01.00.92
    - BERT Control remove Manual configuration
    - Support auto run ISD tool

- USB4 V2 Rx Test Application v01.00.94
    - Support Keysight E5071C for Channel calibration to worst case condition

- USB4 V2 Rx Test Application v01.00.95
    - Support NVL test and beta version before workshop

- USB4 V2 Rx Test Application v01.00.100
   - Fixed FV test condition to test PJ5 only

- USB4 V2 Rx Test Application v00.99.5
   - Support dynamic channel and add prerequisites