------------------ Framework ChangeLog -----------------
EquipmentLib.dll Change Log
=======================================
Last Modified Date: 01 September 2026 5:44:42 AM
Updates: Fixed issue during MP1900a BERT default procedure where the AC Offset setting is not applied, and not turned ON.


GRLSinkTestModule.dll Change Log
=======================================
Last Modified Date: 04 May 2026 5:09:12 AM
Updates: Added Margin Test Settings Tab


GRLBaseFramework.dll Change Log
=======================================
Last Modified Date: 21 December 2025 13:41:22 PM
Updates: build to .net 4.72 allow expired application to load  but disabled report and run fix issue on generate specific test for PDF report for PLL and Tx App


GRLPDFramework.dll Change Log
=======================================
Last Modified Date: 12 January 2026 6:33:20 AM
Updates: Iniital Commit


AppFramework.dll Change Log
=======================================
Last Modified Date: 07 September 2026 13:02:16 PM
Updates: Added OnConnectionChange Event


GRL.Server.dll Change Log
=======================================
Last Modified Date: 12 August 2026 6:33:17 AM
Updates: Update GRLPS logo


------------------ Application ChangeLog -----------------
- USB4 V2 Tx Test Application v00.00.001

- USB4 V2 Tx Test Application v01.00.06
    - Fix condition bug

- USB4 V2 Tx Test Application v01.00.07 01/09/2024
    - Fix deembedding cable issue

- USB4 V2 Tx Test Application v01.00.08 04/09/2024
    - Support 4 ports

- USB4 V2 Tx Test Application v01.00.15 07/03/2024
    - Support distributed process

    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.52.00301

    Test on USB4 Sigtest rev. 0.95
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Tx Test Application v01.00.16 07/18/2024
    - Show SigTest error message in error formate

- USB4 V2 Tx Test Application v01.00.17 08/19/2024
    - Update noise waveform procedure
    - Asymmetric test items will show diagram once

- USB4 V2 Tx Test Application v01.00.18 08/19/2024
    - Update ISI Margin limit to 11 dB

- USB4 V2 Tx Test Application v01.00.19 09/09/2024
    - Update scope intrinsic process, The scope will capture the noise waveform for each channel from 30mV to 100mV, with 5mV intervals.

- USB4 V2 Tx Test Application v01.00.20 11/05/2024
    - Fixed intrinsic waveform bug for ACCM

- USB4 V2 Tx Test Application v01.00.21 12/10/2024
    - TXEQ SigTest will return 9e36 if can not find SigTest result

- USB4 V2 Tx Test Application v01.00.23 12/10/2024
    - Fixed TXEQ SigTest bugs

- USB4 V2 Tx Test Application v01.00.27 07/29/2025
    - Update SNDR limit for CTS v1.0

- USB4 V2 Tx Test Application v01.00.30 03/25/2026
    - Fixed wrong SigTest parameter for Timing and Voltage Measurement test

- USB4 V2 Tx Test Application v01.00.32 04/23/2026
    - Fixed TX EQ bugs for Router DUT type

    Test on Keysight scope software version :
        - Keysight Infiniium UXR-Series System Software rev 11.71.00007

    Test on USB4 Sigtest rev. 0.99
    Test on USB4 ETT rev. 2.0.0

- USB4 V2 Tx Test Application v01.00.34 04/24/2026
    - Fixed TXEQ bugs

- USB4 V2 Tx Test Application v01.00.35 06/22/2026
    - Support frequency variation test

- USB4 V2 Tx Test Application v01.00.36 07/20/2026
    - Support LFPS, Aggressor signal check and LFPS aggressor signal check tests
    - Add "Support Lane Reversal" configuration
    - Add "Crosstalk Enable" configuration
    - Remove "SigTest" configuration, SW will read SigTest version automatically
    - Support "Compliance Mode"

- USB4 V2 Tx Test Application v00.99.02 09/08/2026
    - Support GRLPS GUI
    - Add Prerequisites
    - Main signal support dynamic scope channel