- GRL Shared Capacity Interoperability software v1.00.01
  - Removed Pre Calibration Check step from Calibration
  - Added security checks to invalidate inverted traces from running
  - Temporarily disable any DRP pattern checking

- GRL Shared Capacity Interoperability software v1.00.02
  - Added prompt to notify user that A1-EPR software must be installed at default installation path

- GRL Shared Capacity Interoperability software v1.1.0
  - Update V3 verification logic
  - Additional cosmetic changes
  - Changed trace capture from 100ms to 10ms record interval

- GRL Shared Capacity Interoperability software v1.1.1
  - Fix an issue where incorrect PD index was being displayed in error description of V3

- GRL Shared Capacity Interoperability software v1.1.2
  - Freeze synced PD Message table header for better readability of table

- GRL Shared Capacity Interoperability software v1.1.3
  - Added new batch of A1 Serials to compatibility list for use

- GRL Shared Capacity Interoperability software v1.1.4
  - Disallow tests from running if non English input language is detected

- GRL Shared Capacity Interoperability software v1.1.7
  - Added additional V3 check for capability mismatch, ensuring that there is a source cap advertisement within 2 seconds
  - WMC files are now copied over to the output folder
  - Added new Other verification check to see if VBUS is vSafe0 before DUT power ON

- GRL Shared Capacity Interoperability software v1.1.8
  - Added new batch of A1 Serials to compatibility list for use

- GRL Shared Capacity Interoperability software v1.1.10
  - Added logic capability to process EPR related PD messages

- GRL Shared Capacity Interoperability software v1.1.11
  - Adjusted report color scheme and a new color to represent V1 verification potential power overlap between source cap and negotiated power
  - Added new batch of A1 Serials to compatibility list for use
  - Minor adjustments to cater for SPR AVS
  - Calibration data now contains the version it was calibrated on
  - Removed certain columns from report table as it was unnecessary and distracting when reading the results

- GRL Shared Capacity Interoperability software v1.1.12
  - Updated sink devices for tests

- GRL Shared Capacity Interoperability software v1.1.13
  - Updated sink name for Apple MacBook M4 EPR

- GRL Shared Capacity Interoperability software v1.1.15
  - Minor fix for validation V3
  - Updated instructions for test to attach/detach A1-EPR from DUT side

- GRL Shared Capacity Interoperability software v1.1.16
  - Updated licensing functionality

- GRL Shared Capacity Interoperability software v1.1.17
  - Added new batch of A1 Serials to compatibility list for use

- GRL Shared Capacity Interoperability software v1.1.18
  - Enabled synchronized PD messages printing despite the DUT being a DRP product
  - Added additional checking for V3

- GRL Shared Capacity Interoperability software v1.1.19
  - Fix minor issues regarding incorrect data reporting
  - Updated some report description and titles

- GRL Shared Capacity Interoperability software v1.1.20
  - Added new batch of A1 Serials to compatibility list for use

- GRL Shared Capacity Interoperability software v1.1.24
  - Read the gang power budget from the VIF field the CTS specifies
    (Port_Source_Power_Gang_Max_Power), falling back to the product total; also accept
    the renamed Total_Source_Power_Deliverable field used by newer VIF templates
  - V4 now measures each contract's own settle time instead of a whole section, removing
    false "did not settle within 3s" failures
  - The source capability VBUS range check no longer runs on contracts that never
    completed, contained a Hard Reset, or fall inside the operator detach window
  - V5 now always states why it failed when both ports carry reset events

- GRL Shared Capacity Interoperability software v1.1.26
  - The "VBUS is vSafe0 before DUT power ON" check no longer assumes the DUT powers on
    three seconds into the capture; it now stops at the first CC line or PD activity, so a
    normal attach followed by VBUS coming up is no longer reported as a failure
  - Before an explicit contract, VBUS is now accepted at vSafe0 or vSafe5V (4.75V to 5.5V)
    per the USB Type-C specification, instead of the previous 0V to 3V range
  - VBUS is no longer judged while the CC line shows the port detached, so unplugging a
    sink is no longer reported as the DUT dropping VBUS
  - VBUS removal during a Power Role Swap is no longer charged against the preceding
    source capability
  - Verification remarks now report the voltage actually measured instead of always 0V
  - Verification rows are labelled with the condition being run instead of always C1
  - The report no longer prints a W after the A1 serial numbers